Rant: chased a phantom pitot heat fault for 14 hours over a chafed wire I could've spotted in 10 minutes
Last month on a King Air 200 down in Tucson, the pitot heat breaker kept popping on the right side, so I pulled the probe, swapped the element, and still chased the same fault through two full days. Turns out the wire had rubbed bare against a clamp way up in the wing root where nobody thinks to look, and I only found it after 14 hours of tracing continuity like a rookie. How do you all handle intermittent shorts like this before you burn half a shift on them?